Filling and Capping Directions

You will save yourself time and problems down the road. Like leaks, clogs and poor performance.

You may also void your ACTIVE™ warranty by not following these instructions.

avd-all-ceramic-eazy-press-glass-cartridge-0-5-ml-0-7mm-37594715914488.jpg__PID:d6bf28fb-4a67-4b6a-a081-4c07fcaf5a63

Cartridge and Disposable Filling and Capping

Recommended needle sizeIdeal fill temperatureCapping time
18-20 gauge90 degrees F (thinner oil)
135 degrees F (thicker oil)
3 mins or less
(depending on viscosity)
filling-capping1.jpg__PID:72aeef2f-dc2d-4ff4-b00a-c62ea81e7e55

Insert a blunt tip 18-20 gauge needle into the space between the center airway tube and the inner wall of the cartridge body. 
CAUTION: do not allow oil to enter the center airway tube.

filling-capping2.jpg__PID:70a807c6-4465-4438-a914-7b986de90580

The ideal fill temperature will allow for filling and capping before the oil saturates the atomizer.

filling-capping3.jpg__PID:4a580297-9817-4315-b5a3-ed028fc73278

Oversaturation from hot filling, thin oils, and/pr slow capping will cause flooding, clogging and leaking.

filling-capping4.jpg__PID:54bb0feb-b756-41d4-9600-d15c3ced19c1

Do not overfill your cartridges! Leave a headspace of 2.5mm at the top of the glass tank for the mouthpiece to seat or it may cause bulging seals when capping. Overfilling may force fluid through the atomizer.

filling-capping5.jpg__PID:1351abe8-19d4-45e3-9fb5-acaec67ee4de

Cap within 3 minutes after filling. We recommend a shorter period of time for thinner oils.  Immediately after filling, cap the cartridge with the mouthpiece until it's fully seated.

filling-capping6.jpg__PID:fb66cb7a-8300-4c14-afd8-1d28f0875360

Make sure the mouthpiece is properly aligned and straight. Press the mouthpiece down vertically (and not at an angle) using level, even pressure, until you hear a click. This sound indicates the mouthpiece is fully seated.

filling-capping7.jpg__PID:c031d276-cd22-4ca3-b507-daa93cdfbd48

You can seat the mouthpiece by hand, but a light duty arbor press and jig are recommended. Do not use a hammer or mallet!

filling-capping8.jpg__PID:75f1ac1a-99d3-441e-8a75-084cc77ddb19

Pressing at an angle can lead to damage, improper sealing / bulging, leakage and cracking of the glass tank.

filling-capping9.jpg__PID:7ae092cd-d261-4023-8eff-59a033989f4b

If too much pressure is applied during capping, you can damage the cart or silicone end caps. Check the pressure carefully.

filling-capping10.jpg__PID:ba25957d-9715-44ca-ac13-482bfb62c23d

You cannot remove the mouthpiece once it is fully seated without damaging the cartridge or the mouthpiece.

filling-capping11.jpg__PID:57c130f4-a927-41c3-a32a-f96e0407b4e0

Depending on your oil's viscosity, let your cartridges stand for between 30 minutes to 12 hours before using. During this time, the oil is priming the atomizer. More viscous oils will require more time.

AVD_Stem Black with Black Vortex.png__PID:73545992-b022-4550-8503-b221e1e70980

Stem All-In-One Filling and Capping

Recommended needle sizeIdeal fill temperatureCapping time
14-20 gauge90 degree F (thinner oils)
135 degrees F (thicker oils)
3 mins or less
(depending on viscosity)
filling-capping12.jpg__PID:d00e1634-e4b4-4edf-abdf-a74ebf434429

Insert a blunt tip 14-20 gauge needle into the space between the center airway tube and the inner wall of the cartridge body.
CAUTION: do not allow oil to enter the center airway tube.

filling-capping13.jpg__PID:cdbc8c77-d4ea-4d76-85cf-d8725b95bdb5

The recommended oil temperature range at time of filling is 90 degrees F- 135 degrees F.  The ideal fill temperature will allow for filling and capping before the oil saturates the atomizer.

filling-capping14.jpg__PID:2103b7c1-5c73-4e5e-8755-fb5925d55818

Oversaturation from hot filling, thin oils, and/or slow capping will cause flooding, clogging and leaking.

filling-capping15.jpg__PID:8144eabd-e14b-46cf-b32c-d3b2d07ade0b

Do not fill above the pressure relief hole (10mm from top of tank). If the cartridge is overfilled, fluid will be forced through the atomizer and leak out of the bottom of the cartridge when the mouthpiece is capped.

filling-capping16.jpg__PID:3e1f60ca-eaed-470e-b8a7-d321c2e52fe3

Cap within 3 minutes after filling. We recommend a shorter period of time for thinner oils. Immediately after filling, cap the cartridge with the mouthpiece until it is fully seated.

filling-capping17.jpg__PID:ecf83469-395b-4072-8ab0-036fe2bebcba

Mechanical assistance such as an arbor press is required to fully seat the mouthpiece.  About 66lbs of force (30kgf) is needed to cap a single Stem.

filling-capping18.jpg__PID:bb5b71fd-bbc4-4f90-a5db-ead0724faa0b

Make sure the mouthpiece is properly aligned and straight. Press the mouthpiece down vertically (not at an angle) using level, even pressure, until there is no gap between the mouthpiece and body.

filling-capping19.jpg__PID:835eadcf-5bff-469d-8709-973e5f4803ce

Angled mouthpieces can damage the unit or require excessive force to close.

filling-capping20.jpg__PID:3d1f8a68-5c7a-4fad-ae81-5870cd1789a9

Use an arbor press to cap. Do not cap manually by hand. Do not use a hammer or mallet!

filling-capping21.jpg__PID:1dfb8afe-9aaa-4510-9ae7-78e31913b944

Do not twist or rotate the mouthpiece while it is being inserted.

filling-capping22.jpg__PID:e04690db-b596-446b-94cd-e8919fbcd25e

Once the mouthpiece is fully seated, it cannot be removed without damaging the device or the mouthpiece.